| Water @ 125F Elon Sod. Sulfite Hydroquinone Sod. Carbonate Sod. Hydroxide Water to make | 750.0ml 4.0g 72g 16g 56g 7.5g 1.0L |
|
Add the replenisher to the developer tank so as to maintain the level of solution. Where the tank is in continuous use, a quantity of replenisher equal to that of the original developer may normally be added before the solution is discarded Available as an Ilford packed chemical in sizes to make 1 gallon. In two 80 ounce units British Imperial measure of working strength solution. | |