| Water @ 125F Elon Sod. Sulfite Hydroquinone Borax (cryst.) Water to make |
750.0ml 3.0g 100g 7.5g 20g 1.0L |
Add the replenisher to the developer tank so as to maintain the level of
solution. Where the tank is in continuous use a quantity of replenisher equal to
that of the original developer may normally be added before the solution is
discarded. Available as an Ilford packed chemical in sizes to make 80 ounces
British Imperial measure, of working strength solution.
| |